Operating Instructions for Using Telinject Darts

 

A Telinject Dart assembled and ready for use (when safety cap is removed).

 

Step 1

Remove the satabilizer from the back of the dart.
If the dart is pressurized, de-pressure it with the venting pin.

 

Step 2

Move the rubber plug with the 20cc air filler syringe and connector to a position that allows a little more room inside the drug chamber than required for the volume of the drug to be used.

 

Step 3

1. Seal the side opening of the special needle with the sealing sleeve.

2. Fill the drug syringe with the required drug.

 

Step 4

Transfer the drug slowly into the drug chamber of the dart. Syringe tip must always remain dry and free from grease. Remaining small air bubbles in the drug chamber are harmless.

 

Step 5

Push the special needle firmly onto the body of the dart. Cover needle and dart with the safety cap.
Now the dart can be transported safely.

 

Step 6

IMPORTANT NOTE. Although the diagram above is shown horizontally to fit on this web page, in real life, the syringe MUST be held vertically with the drug chamber on top, and the vent piston in the air chamber pointing down towards the ground.

When ready to use, presurize the dart with the air filler syringe and connector. Hold dart upright and fill air from the bottom to top. Important: Vent piston must point downwards!

 

Step 7

Attach the stabilizer firmly to the end of the dart with a twisting motion.
Remove the safety cap
The dart is now ready for action.

 

Go back to the top of the page.